The data contained herein constitutes confidential information of Material Bank, proprietary in nature. You and your organization have access to this information as a result of agreeing to the Standard Terms and Conditions detailed in your Brand Partner Agreement. These terms state this confidential information shall not be distributed or shared with others outside of your organization or with any of your affiliate companies. By proceeding, you acknowledge and agree to use the contained information exclusively as detailed in your Brand Partner Agreement’s Standard Terms and Condition.If you have any question as to the use of this data contact us at brandservices@materialbank.com.
The EFL/SP100 is a UL Classified heat responsive device and position indicator switches (combined as a single unit) used in conjunction with Ruskin fire/smoke dampers. The EFL is standard on all fire/smoke dampers ordered with electric actuators. The EFL/SP100 will be provided when an electric actuator and separate SP100 position indicator switches are ordered. The EFL closes and locks the damper when temperatures exceed 165°F (74°C) or 212°F (100°C) or 250°F (121°C) or 350°F (177°C) depending on model ordered and installed. The EFL/SP100 must be factory installed and cannot be added in the field. Replacement EFL/SP100’s may be field installed with the approval of the local authority. OPERATION Fire Conditions – When temperatures in excess of 165°F (74°C), 212°F (100°C), 250°F (121°C) or 350°F (177°C) are detected, the damper will close and lock. Upon cessation of fire conditions the damper can be reopened by pressing the reset button located on the EFL/SP100 assembly. The SP100 will allow for indication of damper position during fire conditions. Smoke Conditions – When smoke is detected (detector optional) the damper will close and lock until the smoke signal ceases (or smoke detector resets). The system will then reset and the damper will open. The SP100 will allow for indication of damper position during smoke conditions, The damper may be closed at any time by placing the control switch (optional) in the CLOSED position, If the EFL/SP100 is tripped accidentally or during system testing, the EFL/SP100 must be reset by pressing the RESET button located on the EFL/SP100 assembly, Refer to the appropriate damper installation instructions for details on damper installation.