MCM Acoustical Micro Perforated wood panels have a natural wood veneer laminated to 5/8 in (16mm) FR MDF. Only then is the face microperforated with 0.5mm (1/50 in) perforations and the rear perforated for acoustical performance. This minimizes the risk of delamination or hole clogging common to panels that are laminated after perforation.
Materials
Surfaces/Wood
Size
5 ft x 10 ft (1.5 m x 3 m)
Custom Capabilities
Other veneers are available upon request. If you wish to specify a wood species that is not mentioned on the Finishes page, kindly contact MCM Acoustical to confirm its consistent availability. All veneers can be custom stained. Panels can also be painted
CELING PANEL - DIRECT MOUNTING SYSTEM: MCM Acoustical's Direct Mounting system is designed to attach ceiling panels directly to ceiling grid using z-clips; Panels weigh between 3 and 4 pounds per square foot, so use heavy-duty C-channels and furring channels; Suspend the Grid with #12 Gauge hanger wire or equivalent; Hang wire directly from building structure with a maximum spacing of 4ft.; Attach plywood strips with z-clip track across furring channels as per assembly drawing, available on request; Assembly drawing available in download section; WALL PANEL - DIRECT MOUNTING SYSTEM: MCM Acoustical's Direct Mounting system is designed to attach wall panels directly to wall substrate using z-clips; Wall substrate can be 3/4 in thick x 3 in wide plywood strip or hat / furring channel screwed directly to wall frame; Aluminum z-clip tracks are screwed to wall substrate; Aluminum z-clips are attached to the back of the wall panels with wood screws provided. Typically mounting holes are factory located and pre-drilled. Spacing between clips must not exceed 24 in in both directions vertical and horizontal; Aluminum z-clip attached to the back of wall panel interlock with Aluminum z-clip track attached to wall substrate; Assembly drawing available in download section
Manufacturer Notes
Like any other architectural natural wood products, all MCM Acoustical products are to be acclimatized inside a controlled interior environment for at least 75 hours before installation. During storage prior to installation, during installation, and after installation the relative humidity level of 35% - 55% and temperature range of 20°-27°C (68°-81°F) must be maintained
The Microperforated Panels are Class A fire rated interior wood finish products as per ASTM E84 and CAN/ULC S102 tested in an accredited NVLAP test facility as a finished composite product using Class A components
Acoustics
In addition to the microperforated face of the panel, the MDF core is perforated to improve sound absorption. A black mat is laminated to the rear of the product to create a substantial acoustic performance of up to 1.05 NRC
MCM Acoustical designs and builds custom wood panels for walls and ceilings to provide the optimal sound absorption in your space. Established in 2001, MCMA has 20 years of experience in manufacturing acoustical wood products.
Choose the language you’d like to browse the site in.
{
initFormValidation();
});">
Select an Associated Product
Material Bank
Business Intelligence
Term & Conditions
The data contained herein constitutes confidential information of Material Bank, proprietary in nature. You and your organization have access to this information as a result of agreeing to the Standard Terms and Conditions detailed in your Brand Partner Agreement. These terms state this confidential information shall not be distributed or shared with others outside of your organization or with any of your affiliate companies. By proceeding, you acknowledge and agree to use the contained information exclusively as detailed in your Brand Partner Agreement’s Standard Terms and Condition.If you have any question as to the use of this data contact us at brandservices@materialbank.com.
MCM Acoustical Micro Perforated wood panels have a natural wood veneer laminated to 5/8 in (16mm) FR MDF. Only then is the face microperforated with 0.5mm (1/50 in) perforations and the rear perforated for acoustical performance. This minimizes the risk of delamination or hole clogging common to panels that are laminated after perforation.
CELING PANEL - DIRECT MOUNTING SYSTEM: MCM Acoustical's Direct Mounting system is designed to attach ceiling panels directly to ceiling grid using z-clips; Panels weigh between 3 and 4 pounds per square foot, so use heavy-duty C-channels and furring channels; Suspend the Grid with #12 Gauge hanger wire or equivalent; Hang wire directly from building structure with a maximum spacing of 4ft.; Attach plywood strips with z-clip track across furring channels as per assembly drawing, available on request; Assembly drawing available in download section; WALL PANEL - DIRECT MOUNTING SYSTEM: MCM Acoustical's Direct Mounting system is designed to attach wall panels directly to wall substrate using z-clips; Wall substrate can be 3/4 in thick x 3 in wide plywood strip or hat / furring channel screwed directly to wall frame; Aluminum z-clip tracks are screwed to wall substrate; Aluminum z-clips are attached to the back of the wall panels with wood screws provided. Typically mounting holes are factory located and pre-drilled. Spacing between clips must not exceed 24 in in both directions vertical and horizontal; Aluminum z-clip attached to the back of wall panel interlock with Aluminum z-clip track attached to wall substrate; Assembly drawing available in download section
Manufacturer Notes
Like any other architectural natural wood products, all MCM Acoustical products are to be acclimatized inside a controlled interior environment for at least 75 hours before installation. During storage prior to installation, during installation, and after installation the relative humidity level of 35% - 55% and temperature range of 20°-27°C (68°-81°F) must be maintained
The Microperforated Panels are Class A fire rated interior wood finish products as per ASTM E84 and CAN/ULC S102 tested in an accredited NVLAP test facility as a finished composite product using Class A components
Acoustics
In addition to the microperforated face of the panel, the MDF core is perforated to improve sound absorption. A black mat is laminated to the rear of the product to create a substantial acoustic performance of up to 1.05 NRC