- Acoustics
- ASTM E2179 / ISO 140 Sound Absorption - ?IIC 11, Lw8dB (2mm), ?IIC 14, Lw10dB (3mm), compare only ? values
- Compression
- ASTM F970 Static Load Limirt - Residual compression of 0.003in with 800 lbs (= 0.005in with 250 lbs is required); Rolling Load Limit = 550 lbs/sq in, with no forklift traffic
- Flammability
- ASTM E648 (NFPA 253, NBSIR 75 950) - 0.97 Class 1 (2mm), 1.03 Class 1 (3mm), = 0.45 watts/sq. cm is required; ASTM E662 Smoke Density (NFPA 256, NBS) - 196 flaming and 207 non-flaming (2mm), 376 flaming and 256 non-flaming (3mm), <450 is required; CAN/ULC-S102.2 Surface Burning - FSC1 of 125 and SD of 370
- Hardness
- ASTM D2240 Shore type “A” - 92 achieved (2mm), 82 achieved (3mm), = 85 is required
- Light Blocking
- Complete
- Maintenance
- No finishing, waxing, or sealing required. Refer to Maintenance attachment for details
- Slip Resistance
- ASTM D2047 Static coefficient of friction, Neolite dry 0.93 and Neolite wet 0.90 (2mm), Neolite dry 0.92 Neolite wet 0.91 (3mm), = 0.5 is required. Not recommended for ramps